Search EA-Software.com:

KNOWLEDGE BASE ARTICLES

Please use the 'quick jump' menu below to find an appropriate solution to your question. If your question is not present, click here to return to the Tech Support page for contact information.

QUICK JUMP:
1. Why does the program always ask for a cd-rom?
2. What is the password to get into the manager?
3. Why do I get runtime errors when running on a version of Windows past 95?
4. Why do I get the error message, "dbutil_sys_settings - opendb: Management Error #-20064" when starting a program?
5. Why do I get a "Management Error - 20060" when executing a program?
6. Why do I get "-20020. Cannot find foxpro" error message?
7. When trying to view a report in Arithmetic Skills Assessment, "Operation Halted!" appears and report cannot be viewed.
8. Math for Everyday Living Manager does not work with my other EA Titles
9. Informal Reading Test will not run on IMAC 9.0 and gives "error trying to find a file on your system -48" when launched.
10. EA software, "DB Update Pat Cannot be Found."
11. Installing Diascriptive Reading II
12. Program does not appear on the workstation
13. Program will not work with multiple users
14. Error when attempt to log into manager that program cannot be found.
15. Video does not play, instead see black box.
16. Video is choppy
17. Error when viewing video
18. When attempt to use manager, "Application quit unexpectedly."
19. Message, "Manager not found" when attempt to run the EA Manager
20. Network version of thinking Like a Scientist, if two or more students try to get get into the same level, "Problem opening TLS1_int.dxr -4
21. "dbutil_sys_settings - opendb: Management Error #-20064" when launching EA's Learning Styles Inventory network version
22. Magic Letter Factory "Script Error: handler not defined # fileio"
23. Educational Activities Software won't allow installation to hard drive.
24. "Please Call Your Teacher" is displayed an no options are available.
25. Systems_setting; error-11012 cannot get data pass" when launching program.
26. Sound Sentences 2
27. Can I use the keyboard to tab between screens in Sound Sentences II?
28. Why won't The Magic Letter Factory run in WindowsXP?
29. Unknown error message - Magic Letter Factory on Windows XP.
30. Sound Sentences II worksheets all have the title Classroom Activities.
31. Cannot find dll's during install.
32. Why do the .cda files ask for the CD when they have been copied from the EAS Citzenship: Questions and Dictation CD to a hard drive?
33. When attempting to launch Diascriptive Language Arts Sentence Nick - Sense, a Windows workstation gives the following error message: "invalid TX object handled Category: Invalid argument (Invalid object) function: xvt-tx-get-num-pars.... File: TTX.c line: 903."
34. When launched from more than one workstation, the error message "Application is already in use...DBUtils get data management, Error #
35. "There are no lessons installed" when attempt to launch EA Manager.
36. The video clips display above the viewing area.
37. Diascriptive Reading will not start.
38. When I record my voice, I only hear static.


Question:
Why does the program always ask for a cd-rom?

Answer:
SYMPTOMS:
Always asks for cd-rom when program is started.

CAUSE:
By design, the standalone EA titles must have a cd-rom in the drive in order to run.

SOLUTION:
Send Hard Drive Installer Disk, use the cd-rom or change to Real Achievement (RA).

RETURN TO TOP

Question:
What is the password to get into the manager?

Answer:
SYMPTOMS:
The EA management console asks for a password to enter.

CAUSE:
By design.

SOLUTION:
The password is "teacher".

RETURN TO TOP


Question:
Why do I get runtime errors when running on a version of Windows past 95?

Answer:
SYMPTOMS:
Running a DOS version of an EA product results in a "runtime" error.

CAUSE:
Past 95, Windows does not have a true DOS environment (only an emulator) and therefore occasionally has problems running some DOS based
programs.

SOLUTION:
Update your version of Windows with a true DOS emulator.

RETURN TO TOP


Question:
Why do I get the error message, "dbutil_sys_settings - opendb: Management Error #-20064" when starting a program?

Answer:
SYMPTOMS:
The following error message appears when starting the program: "dbutil_sys_settings - opendb: Management Error #-20064" on a Macintosh
network. The program does not run.

CAUSE:
During installation, the program was installed directly to the server. This sometimes locks the files and/or turns the sharebit off. This may not
allow anyone, or sometimes just one student, to access the program.

SOLUTION:
Reinstall the program from a workstation copy. Specifically, delete the current installation. Install to a Macintosh workstation, then test the local workstation copy. If it works, Copy and Paste it up to the server. Configure all the workstations and test it further. (The install to a workstation first, seems to make sure that the settings end up correct when it is finally placed on the server.)

RETURN TO TOP


Question:
Why do I get a "Management Error - 20060" when executing a program?

Answer:
SYMPTOMS:
"Management Error - 20060" occurs every time a program is launched. The program cannot be started.

CAUSE:
The current network user does not have the necessary permissions.

SOLUTION:
Change permissions so that users can read, write, execute, create files, and delete files within the entire installation of the program.

RETURN TO TOP


Question:
Why do I get "-20020. Cannot find foxpro" error message?

Answer:
SYMPTOMS:
When launching any of the EA products from the workstations the application gives an error "-20020". When trying to launch the EA Manager
from the server it gives an error that it "cannot find foxpro DBF file".

CAUSE:
Old version of product.

SOLUTION:
Call customer service for the latest version.

RETURN TO TOP


Question:
When trying to view a report in Arithmetic Skills Assessment, "Operation Halted!" appears and report cannot be viewd.

Answer:
SYMPTOMS:
In Arithmetic Skills Assessment, "Report Operation Halted! This report is not available for viewing." is recieved when attempting to view ASAT Class (or Student) Mastery List report. Report cannot be viewed.

CAUSE:
Report is not viewable by design, only printable.

SOLUTION:
By design.

RETURN TO TOP


Question:
Math for Everyday Living Manager does not work with my other EA Titles

Answer:

SYMPTOMS:
The Math for Everyday Living Management system does not work.

CAUSE:
The Math for Everyday Living series has a different manager than other EA software programs.

SOLUTION:
Utilize the two different management systems

RETURN TO TOP


Question:
Informal Reading Test will not run on IMAC 9.0 and gives "error trying to find a file on your system -48" when launched.

Answer:

SYMPTOMS:
Informal Reading Comprehension Test Standalone CD-run Installation does not work on IMAC running OS 9.x and gives "error trying to find a file on your system -48" when launched. (Also had customer report this on OS 8.5)

CAUSE:
Software Bug

SOLUTION:
Send the customer Hard Drive Install for Informal Reading Comp. Test

RETURN TO TOP


Question:
EA software, "DB Update Pat Cannot be Found."

Answer:

SYMPTOMS:
Whenever I enter my EA software, receive a message that the DB Update Cannot be Found.

CAUSE:
Software Installed Incorrectly.

SOLUTION:
Reinstall Software. (If running Network, be sure to run workstation installers on every workstation.)

RETURN TO TOP


Question:
Installing Diascriptive Reading II

Answer:
Please use these directions for installing and operating the Diascriptive Reading II program:

First, make sure any virus protection is disabled during installation.

Put the CD-ROM in the drive and click on it to open it. You should see a box titled, "DRII SA Installation."

Icons should be visible. On the left there should be an icon labeled, " EA Manager CD Installer." On the right, "DRII SA Installer."

Click 2x on the "EA Manager CD Installer" icon and follow the on-screen instructions. When this is completed, click on the "DRII SA Installer" and follow the on-screen instructions. The final screen you should see will say at the bottom, "Update complete."

To run the program, click on the DR II "book" icon in that original box. You can drag this icon to the desktop to make it easier for the students to access the program.

To check scores in management, open the EA Manager file, which is the icon with a magnifying glass. The password is "teacher." You may want to hide the Manager from your students. I don't know how you manage the desktop, i.e., if you use Foolproof, At-Ease, etc.

If you find this program to be what you're looking for, we do have a hard drive installable program, which eliminates the need for students to handle the CD's. This is purchase option available to you.

Occasionally, due to screen savers, insufficient memory, or computer "gremlins," the connection between the management and the program doesn't occur and you will see an error message when students attempt to access the program. In that case, go to the EA Manager file on the hard drive, click and open it, scroll down to a file labeled "addprogs," click on it and the connection should be made (you will see a message "update completed"). Use this only if there's a problem.

RETURN TO TOP


Question:
Program does not appear on the workstation

Answer:
On a Macintosh network, the program will not appear on the workstation desktop. To resolve, manually create an alias an paste it to the desktop.

RETURN TO TOP


Question:
Program will not work with multiple users

Answer:
Turn on Shared Bit on Macintosh - (Unsure of error or accuracy of resolution)

RETURN TO TOP


Question:
Error when attempt to log into manager that program cannot be found.

Answer:
When you log into the manager using your password, you get an error that indicates no programs are associated with the EA Manager. Resolution: In the folder, __\EA\mgmt2010, run addprograms.exe. This is a brief executable file and will update the manager. Once complete, log back into EA Manager successfully.

RETURN TO TOP


Question:
Video does not play, instead see black box.

Answer:
When you log into the program, the video does not play. There is a black box covering the graphic. Resolution: Install the version of Quick Time from the CD.

RETURN TO TOP


Question:
Video is choppy

Answer:
Video plays, but is choppy, fragmented, bouncing, rough Resolution: Set color settings to thousands of colors.

RETURN TO TOP


Question:
Error when viewing video

Answer:
Error message when attempting to view the video. Resolution: Install the version of Quick Time on the CD

RETURN TO TOP


Question:
When attempt to use manager, "Application quit unexpectedly."

Answer:
When you are using the EA Manager, get message that, "The application quit unexpectedly." Resolution: Increase Preferred Memory.

RETURN TO TOP


Question:
Message, "Manager not found" when attempt to run the EA Manager

Answer:
SYMPTOMS: Receive error, "Manager is not found" when you attempt to launch the EA Manager.

CAUSE:
1. Manager was not installed or,
2. Manager was installed after the application

SOLUTION:
1. Install Manager, and then,
2. Run "Add Programs"

RETURN TO TOP


Question:
Network version of thinking Like a Scientist, if two or more students try to get get into the same level, "Problem opening TLS1_int.dxr -4

Answer:
SYMPTOMS
Network version of thinking Like a Scientist, if two or more students try to get get into the same level, "Problem opening TLS1_int.dxr -49." error messsage appears.

CAUSE
Files are not sharing properly.

SOLUTION
Mark all files as "read-only" (also mark as "sharable" if on a Novell server).

RETURN TO TOP


Question:
"dbutil_sys_settings - opendb: Management Error #-20064" when launching EA's Learning Styles Inventory network version

Answer:
SYMPTOMS:
The following error message appears when launching EA's Learning Styles Inventory network version: "dbutil_sys_settings - opendb: Management Error #-20064" on a Macintosh network. The program does not run.

CAUSE:
Bad installation or problem with the Data folder.

SOLUTION:
Complete uninstall/reinstall. Search hard drive of server and any workstations receiving the error for "learning styles" or "lsi". Trash any files found. Run Net installer from the CD at the WORKSTATION. If it says any learning styles components are found, select the option to delete the files and run the installer again. Repeat these steps until the installer displays instructions for installation and allows you to "switch
path" of installation to the mounted server's hard drive. Click "quit" after a message tells you the workstation is setup to run Learning Styles. Navigate through mounted drive for Learning Styles Inventory folder and create an alias of the yellow & black Learning Styles Inventory icon. Drag the alias icon to the desktop of the workstation. Double-click on desktop icon to start the program.

RETURN TO TOP


Question:
Magic Letter Factory "Script Error: handler not defined # fileio"

Answer:
SYMPTOMS:
When attempting to run The Magic Letter Factory on a Windows2000 computer the user gets "Script Error: handler not defined # fileio." May also get "The application or .dll C:\WINNT\System32\wing.dll is not a valid windows image. Please check this against your Windows installation disk."

CAUSE:
The program must be launched from the LFCTRY16.EXE file on the Magic Letter Factory CD. Also, the program requires QuickTime 2.1.2 to be installed on the computer.

SOLUTION:
Launch the Magic Letter Factory program with the LFCTRY16.EXE program on the CD-ROM. If a message states that QuickTime needs to be installed, then following these directions: Browse to the QTW212 folder on the CD-ROM. Run QT16.EXE. Following the on-screen directions to install QuickTime. After QuickTime 2.1.2 has been sucessfully installed, launch the Magic Letter Factory program from the LFCTRY16.EXE file on the CD-ROM.

RETURN TO TOP


Question:
Educational Activities Software won't allow installation to hard drive.

Answer:
SYMPTOMS:
When you attempt to install EA Software to a hard drive, you are given a message that you cannot install the software to a hard drive. CAUSE:
Customer received the CD labeled "Custom Network Installer." This CD can only be installed to a server location.

SOLUTION:
Install to a server, or if a customer does not have a server, send the Hard Drive Installer Disk.

RETURN TO TOP


Question:
"Please Call Your Teacher" is displayed an no options are available.

Answer:
SYMPTOMS
"Please Call Your Teacher" is displayed and no options are available.

CAUSE
By design the program stops due to the student's performance.

SOLUTION
Press CTRL+A to escape.

RETURN TO TOP


Question:
Systems_setting; error-11012 cannot get data pass" when launching program.

Answer:
SYMPTOMS
"Systems_setting; error-11012 cannot get data pass" when launching program. Program does not run.

CAUSE
The management system was not installed or was installed after the program.

SOLUTION
Uninstall all eas software, install the manager and then install the program. OR: Disable security software (i.e., Foolproof or At Ease) prior to installing.

RETURN TO TOP


Question:
Sound Sentences 2

Answer:
Bundle Install Code:
TR5097

RETURN TO TOP


Question:
Can I use the keyboard to tab between screens in Sound Sentences II?

Answer:
SYMPTOMS:
Program does not respond to keyboard commands.

CAUSE:
By design. A mouse is required to use the program.

SOLUTION:
A mouse is required to use the program.

RETURN TO TOP


Question:
Why won't The Magic Letter Factory run in WindowsXP?

Answer:
***THIS INFORMATION IS ONLY A "HEADS-UP" FROM ALAN STERN. I HAVE NOT RECEIVED A CALL ABOUT IT AND THE FOLLOWING INFORMATION HAS NOT BEEN PROVEN.

SYMPTOMS:
The Magic Letter Factory will not work when run in WindowsXP.

CAUSE:
The version of Macromodia used to develop The Magic Letter Factory is not compatible with WindowsXP.

SOLUTION:
First, create an icon on the desktop for The Magic Letter Factory. Then, modify it to run in Windows98 compatibility mode with 256 colors.

RETURN TO TOP


Question:
Unknown error message - Magic Letter Factory on Windows XP.

Answer:
SYMPTOMS
Magic Letter Factory does not run properly on Windows XP machines.

CAUSE
It is an older program designed for Windows 98 and has not been tested yet on XP. Possibly, the incompatibility is with Macromedia Director, not MLF.

SOLUTION
Run XP's Compatibility Wizard set to Windows 98 for MLF. NOTES
Refer to MS Support Article on how to use the Compatiblity Wizard:
http://support.microsoft.com/search/preview.aspx?scid=kb;en-us;Q301911

RETURN TO TOP


Question:
Sound Sentences II worksheets all have the title Classroom Activities.

Answer:
SYMPTOMS
Sound Sentences II worksheets all have the title Classroom Activities.

CAUSE
Left over from SS I.

SOLUTION
May be changed in future release.

RETURN TO TOP


Question:
Cannot find dll's during install.

Answer:
SYMPTOMS
According to customer.... The workstation installation states that the installation completed successfully, however when trying to execute from workstation LSI returns the following errors: Cannot find file xwmtey50.dll
Cannot find file xwmba450.dll Then it can not find file v:\ea\lsi\lsi.exe (where v is the mapped drive where lsi is installed on the network)

CAUSE
Unknown.

SOLUTION
Unknown.

WORKAROUND
Customer resolved by copying the named dll's to windows system folder from server to workstations.

RETURN TO TOP


Question:
Why do the .cda files ask for the CD when they have been copied from the EAS Citzenship: Questions and Dictation CD to a hard drive?

Answer:
SYMPTOMS:
When copied to a hard drive from the EAS Citizenship: Questions and Dictation CD, the .cda audio files ask for the CD when launched.

CAUSE:
The Questions and Dictation CD is simply a music CD and when copied from the CD onto a hard drive, the .cda file is simply a shortcut to that track on the CD.

SOLUTION:
Use any music CD audio formatting software to convert the audio tracks into a digital sound file, such as .mp3 or .wav.

RETURN TO TOP


Question:
When attempting to launch Diascriptive Language Arts Sentence Nick - Sense, a Windows workstation gives the following error message: "invalid TX object handled Category: Invalid argument (Invalid object) function: xvt-tx-get-num-pars.... File: TTX.c line: 903."

Answer:
SYMPTOMS
When attempting to launch Diascriptive Language Arts Sentence Sense, a Windows workstation gives the following error message: "invalid TX object handled Category: Invalid argument (Invalid object) function: xvt-tx-get-num-pars.... File: TTX.c line: 903."

CAUSE
Program did not install properly.

SOLUTION
Reinstall program.

NOTES
Worked for a customer.

RETURN TO TOP


Question:
When launched from more than one workstation, the error message "Application is already in use...DBUtils get data management, Error #

Answer:
SYMPTOMS
When launched from more than one workstation, the error message "Application is already in use...DBUtils get data management, Error #11025." is received.

CAUSE
The sharebit is not set properly. Likely due to installing from server rather than a workstation.

SOLUTION
Simple uninstall and reinstall will not work... follow the notes below.

NOTES
1. Uninstall
2. Search server drives for eas or lsi remnant files and delete (must be at server to see all system folders)
3. Reinstall LSI from a workstation

RETURN TO TOP


Question:
"There are no lessons installed" when attempt to launch EA Manager.

Answer:
When teacher attempts to view the students' scores, teacher receives the error, "there are no lessons installed."

SOLUTION: Open the EA Manager Folder and locate the program, AddProgs. Double-click on the icon fo AddProgs, follow any on-screen instructions. This program will verify that all EA programs have been recognized properly by the EA Manager. AFter running AddProgs, you can access the EA Manager and view the scores for students who have run the EA applications.

RETURN TO TOP


Question:
The video clips display above the viewing area.

Answer:
SYMPTOM: On Ea programs that display video clips, the video clips display above the viewing area.

SOLUTION: Change computer Display Settings to Small font.
1. Right-Click on the desktop
2. Select Properties.
3. Select the Setting Tab.
4. Change Font settings to Small font.
5. Click Apply.

RETURN TO TOP


Question:
Diascriptive Reading will not start.

Answer:
SYMPTOMS: Click OK to enter Diascriptive Reading and nothing happens.

SOLUTION: Change computer Display Settings to Small font.
1. Right-Click on the desktop
2. Select Properties.
3. Select the Setting Tab.
4. Change Font settings to Small font.
5. Click Apply.

RETURN TO TOP


Question:
When I record my voice, I only hear static.

Answer:
SYMPTOMS: Core Reading and Vocabulary Development programs, after upgrading to a Power Mac, when student records their voice, they only hear static.

SOLUTION: Upgrade customer to current version of Core Reading.

RETURN TO TOP



HOME | CONTACT | DOWNLOADS | LOCAL SUPPORT | INFO
PRODUCTS | MANAGEMENT | CORRELATIONS & SCOPE
DOCUMENTATION | PRICING | TECH SUPPORT | REQUEST INFO | LINKS

© Copyright 2002 Siboney Learning Group a subsidiary of Siboney Corporation.
Traded over-the-counter as SBON.